Li-ion cell — supplier comparison
High riskExpert reviewedVoltline Mobility · Cradle-to-gate · Scenario compareSupplier B cell inventory
Edit NMC 811 baseline and Supplier B cell foreground flows, preserve source evidence, and keep reviewer notes tied to per 1 kwh cell capacity, cradle-to-gate.
Flow register
Select a row to inspect evidence, assumptions, and validation status.
| Flow | Stage | Scenario | Quantity | Factor | Status | DQI |
|---|---|---|---|---|---|---|
| NMC 811 baselineScenario system | Baseline model | NMC 811 baseline | 1 functional unit | 62.00 | Mapped | 8/10 |
| Supplier B cellCurrent scenario | Active model | Supplier B cell | 1 functional unit | 41.00 | Mapped | 8/10 |
| Formation electricity factorAssumption parameter | Energy model | Supplier B cell | 0.34 kg/kWh | 3.70 | Mapped | 9/10 |
| Cathode precursor emission factorAssumption parameter | Supplier route | Supplier B cell | 7.8 kg/kg | 3.10 | Mapped | 8/10 |
| Synthetic graphite shareAssumption parameter | Material choice | Supplier B cell | 58 % | 2.10 | Mapped | 8/10 |
| Solvent recovery rateAssumption parameter | Foreground process | Supplier B cell | 91 % | 0.90 | Needs review | 5/10 |
| Cell manufacturing yieldAssumption parameter | Foreground process | Supplier B cell | 94 % | 1.00 | Mapped | 8/10 |
| Cathode active materialForeground hotspot | Contribution model | All scenarios | 370 index | 3.70 | Mapped | 8/10 |
| Cell formation electricityProcess input | Contribution model | All scenarios | 240 index | 2.40 | Mapped | 9/10 |
| Anode graphite productionProcess input | Contribution model | All scenarios | 160 index | 1.60 | Mapped | 7/10 |
| Electrolyte and separatorProcess input | Contribution model | All scenarios | 120 index | 1.20 | Mapped | 8/10 |
| Pack-ready logisticsProcess input | Contribution model | All scenarios | 110 index | 1.10 | Needs review | 5/10 |
| Use renewable formation electricityScenario action | Improvement queue | Low-carbon supply | 19 % | 1.90 | Mapped | 8/10 |
| Switch to lower-carbon cathode precursorScenario action | Improvement queue | Low-carbon supply | 14 % | 1.40 | Mapped | 7/10 |
Validation checks
Baseline scenario is available for comparison.
Functional basis is attached to the project profile.
Audit notes
Local notes stay attached to the selected flow for review traceability.
Solvent recovery rate is the current inventory evidence focus. Keep its source, assumptions, and validation notes attached before report export.
Smog formation: VOC control evidence is pending for the selected supplier site. Evidence note: Solvent and transport emissions are represented with supplier defaults.